Triol AK06 Low Harmonic
Place an order 
                Distinctive benefits
20°С … +60°С
Operating temperature range
NEMA3R
Enclosure
Built-in
Input harmonic filter
About product
Compliance with IEEE519
Variable Speed Drive AK06 line LH is a reliable and profitable solution based on the line RD, for applications that require compliance with the requirements of IEEE519 standard in the main operating range of the installation.
Built-in input harmonic filter
LH drives provide a minimum level of distortion to the input network due to the built-in input harmonic filter. The rated output current of the VSDs is from 100 A to 2000 A, the supply voltage is 380 V, 50 Hz and/or 480 V, 60 Hz. Triol provides efficient control of installations both with induction and valve motors with specialized authoring control algorithms.
Specifications
| Parameter | Value | 
|---|---|
| Power supply, V | 
 | 
| Input Frequency, Hz | 50±1 and/or 60±1 | 
| Rated output current, A | 100 – 2000 | 
| Overcurrent characteristics | 120% of rated value for 60 sec | 
| Change of frequency task increment, Hz | 0,1 | 
| Efficiency | 96 % | 
| Passive filter efficiency | >98 % | 
| Level of current distortion in the input network THDi | <5% in the load range from 25%* to 100% * operation in the extended load range is optional when specified in the order | 
| DC bus choke | Built-in | 
| Sine filter | Built-in | 
| Capacitor unit (for voltage sags) | Option, outdoor 
					 
 | 
| Braking IGBT | Option, built-in | 
| Braking resistor | Option, outdoor | 
| Electric meter | Option, built-in | 
| GPRS router | Option, built-in | 
| PID mode | YES | 
| HMI | 
 | 
| Output frequency, Hz | 
 
 | 
| PWM frequency | up to 8 kHz depending on VSD type | 
| Speed maintenance accuracy (static) | +/- 10% of rated speed in open-loop system | 
| Control type | 
 
 | 
| Light alarm | “Work”, “Waiting”, “Stop” | 
| Operator Control Voltage | Option: 
					 
 | 
| Number of AI | 2 by default, optional extension +8 | 
| AI type | programmable 4..20 mA, 0..5 mA, 0..10 V (frequency reference / multifunction analog input) | 
| Number of DIN | 2 by default, optional extension +4 or more | 
| DIN type | 24 V, input resistance: 4 kOhm | 
| Number of analog outputs | Option, 4 or more programmable 4..20 mA, 0..5 mA, 0..10 V | 
| Number of Relay Outputs | Option, 8 | 
| Acceleration and deceleration rates | 
 | 
| Insulation | Galvanic isolation between power and user circuits | 
| Insulation resistance | > 5 MOhm | 
| Protection type | 
 | 
| Communication port | Modbus | 
| Physical interface | 
 | 
| Frame Transmission | Modbus RTU | 
| up to 115200 bps | |
| Data format | 8 bits 1 stop bit, no parity | 
| Number of addresses | 1 .. 255 addresses for Modbus | 
| Access method | slave | 
| Enclosure protection | IP20 (Indoor), NEMA3R | 
| Material of enclosure | carbon steel | 
| Operating temperature | -20°С … +60°С (-60°С optional) | 
| Relative humidity | 95 % | 
| Cooling type | Air forced | 
Certificates
- 
                            9001:2015
- 
                            61439-1
- 
                            61000-6-4
- 
                            61000-6-2
- 
                            
 +48737866327